Current transducer DXE2000-KLSIPN=2000

electronic measurement of current: DC, AC, pulsed…, with galvanic separation between the primary and the secondary circuit.

Features

● Easy mounting

● Small size and space saving

● No insertion losses

● High immunity to external nterference

Application Domain

● AC variable speed drives

● Static converters for DC motor drives

● Battery supplied applications

● Uninterruptible Power Supplies

● SWITCHED Mode Power Supplies

●Power supplies for welding applications

Electrical dataTA=25℃,RL=10kΩ)

Rated input: IP=±2000A

Measure range: IPM=±3000A

Rated output voltage: VOUT=±4V

Offset voltage: VO=±20Mv

Supply voltage: VC=±12VDC~±15VDC(± 5%)

Galvanic isolation: VD=50Hz,1min,5KV

Load resistance:RM=≥10KΩ

Linearity: εL =≤1%FS

Overall accuraty:X=±1%FS

Offset voltage drift: VOUT=≤0.5mV/℃

temperature coefficient: VOUT=≤≤0.05%/℃

Current consumption: IC=≤15mA

Response time:TR<10μs

Frequency bandwidth-3db:BW=DC~25KHz

di/dt accurately followed:>50A/μS

Ambient operating temperature:TA=-40~+85℃

Ambient storage temperature:TS=-40~+95℃

Mass: M≈550g

Standards:SJ 20790-2000;JB/T 7490-2007

Mechanical dimension

Mechanical characteristics

General tolerance: ± 1 mm

Other tolerance execution: GB/T 1804-2000-M

Fixing hole size: Disc installationΦ3mm; 15×146

Fastening steel: Installation of busbar M5; Disc installation M4

Recommended fastening torque: 1.2Nm(± 10 %)

Connection of secondary: KF2EDGCV-X5.08-4P

Connector recommended torque: 0.3Nm (± 10 %)